G-60 practice test: torch use of flammable gases

G-60 Certificate of Fitness (COF): Torch Use of Flammable Gases

Torch operators who use oxygen with a flammable gas, LPG or CNG for hot work such as cutting, welding, brazing, soldering and torch-applied roofing. The booklet says any hot work, including torch-applied roofing, must be personally done by a Certificate of Fitness holder.

G-60 exam

35 questions

53 minutes

To pass

70% or more

Multiple choice, touch screen

Where

9 MetroTech

FDNY HQ, Brooklyn

From the FDNY's official G-60 Notice of Exam and study material (Revised January 2026 (Contact/Payment info)), checked October 12, 2026. Download the official booklet (PDF, nyc.gov) and check it before your exam, because the FDNY can change it without notice.

Before you apply

Free G-60 sample: 10 questions

No account needed. You'll see the answer, an explanation and where it is in the official study material after each question.

Question 1 of 10

Under the booklet's important code change, who must personally carry out hot work, including torch-applied roofing?

The full G-60 question bank

347 original questions across 13 topics from the study material, each with an explanation. Practice by topic, then sit timed mocks at the real length (G-60: 35 questions in 53 minutes). 120 of them also appear in our F-60 bank, because the two FDNY booklets set out the same rules there.

One-time payment, 12 months of access, 14-day money-back guarantee. Already bought it? Practice · Timed mock

G-60 practice test questions and answers

The 10 free sample questions above, with the answer, the reason and the place in the official study material. Open one to check it.

  1. 1. Under the booklet's important code change, who must personally carry out hot work, including torch-applied roofing?Show answer
    • A. Any worker, as long as an FDNY permit covers the site
    • B. Only an FDNY-licensed master plumber
    • C. Any worker supervised by a licensed contractor
    • D. A Certificate of Fitness holder

    Answer: D. The code change says all hot work, including flammable gas torch work with or without oxygen and torch-applied roofing, must be done personally by a Certificate of Fitness holder.

    Topic: Certificates and permits · Official study material: Introduction: Certificate of Fitness

  2. 2. Which of these is NOT issued by the FDNY?Show answer
    • A. A site-specific permit
    • B. The hot work program authorization
    • C. A Certificate of Fitness
    • D. A citywide permit

    Answer: B. The hot work program authorization is signed and issued by the responsible person at the premises, not by the FDNY.

    Topic: Hot work authorization and checks · Official study material: Introduction: Hot Work Program Authorization

  3. 3. Which of these is an approved area for hot work, according to the booklet?Show answer
    • A. A warehouse aisle next to baled paper
    • B. An area designed for hot work, such as a jewelry factory workspace
    • C. A floor where the standpipe is impaired, above 75 feet on a construction site
    • D. A boat at a dock that is being repaired

    Answer: B. Hot work may be done in areas designed for it, or in areas the responsible person authorizes after the Fire Code precautions are taken.

    Topic: Approved and restricted areas · Official study material: Part 1, 1.1.1 Hot Work Approved Areas

  4. 4. On May 10, 1999, a Manhattan fire led to NYC's torch rules. How did it start?Show answer
    • A. A welder cutting steel beams in the basement of an apartment building
    • B. Roofers using propane torches to install modified roofing
    • C. An e-bike battery charging overnight
    • D. A gas leak in a restaurant kitchen

    Answer: B. Roofers installing modified roofing with propane torches started a 3-alarm fire that destroyed 30 apartments.

    Topic: Hot work basics and PPE · Official study material: Part 1. Torch (Hot Work) Operation: Torch Fire History

  5. 5. How must the electric cables for arc welding be handled?Show answer
    • A. Left ungrounded to reduce sparks
    • B. Run through doorways and exit paths so they stay out of the work area
    • C. Properly grounded, and placed so they are not a tripping hazard
    • D. Coiled near the work so they stay warm

    Answer: C. Arc welding cables must be properly grounded, must not be a tripping hazard and must not obstruct any means of entry.

    Topic: Combustibles, arc welding and signage · Official study material: Part 1, 1.3.2 Electric ARC Welding Precautions

  6. 6. Torch cutting is done in a building's mechanical room by a contractor with a site-specific permit. It is not a construction site or a roof. What does the booklet say about the fire watch?Show answer
    • A. No fire watch is needed, because the work is indoors and the contractor has a site-specific permit
    • B. Two F-60 fire guards are required
    • C. The torch operator can watch his own work
    • D. A fire watch is required, but the booklet does not require it to be an F-60 holder

    Answer: D. A fire watch is needed for all hot work, but an F-60 fire guard is required only at construction sites, on rooftops or roofing jobs, and for citywide permit holders' torch work.

    Topic: Fire watch and fire guards · Official study material: Part 1, 1.4.2 Fire guard

  7. 7. A propane torch used for torch-applied roofing is an example of which kind of torch?Show answer
    • A. An electric arc welder
    • B. A blowtorch (air-fuel, single tank)
    • C. A thermit welder
    • D. An oxy-fuel torch

    Answer: B. The propane roofing torch is the booklet's example of a blowtorch, which burns fuel mixed with surrounding air.

    Topic: Torch types and uses · Official study material: Part 2, 2.1.1 Blowtorch (Air-fuel) Torch

  8. 8. When fitting a regulator to a gas container, what does the booklet warn against?Show answer
    • A. Checking that the valve is clean
    • B. Over-tightening the regulator nut, which may damage the fitting
    • C. Keeping the valve accessible
    • D. Using a regulator made for that gas

    Answer: B. Make sure valves and regulators are clean, and don't over-tighten the regulator nut.

    Topic: Oxy-fuel and blowtorch procedures · Official study material: Part 2, 2.3.1 Set Up an Oxy-Fuel Torch

  9. 9. How should you identify what gas is in a compressed gas container?Show answer
    • A. By the smell at the valve
    • B. By the stenciled, stamped or labeled name on the container, usually near the neck
    • C. By the color the container is painted, since every supplier uses the same standard colors
    • D. By the weight of the container

    Answer: B. Contents must be clearly identified by stencil, stamp or label. Don't rely on color alone.

    Topic: Compressed gas containers · Official study material: Part 3, 3.1.1 General Guidance

  10. 10. What does acetylene smell like, according to the booklet?Show answer
    • A. Rotten eggs
    • B. Garlic
    • C. Almonds
    • D. Nothing; it is odorless

    Answer: B. The booklet describes acetylene as colorless and extremely flammable, with an odor like garlic.

    Topic: Acetylene, LPG and CNG · Official study material: Part 3, 3.2 Handling and Use of Acetylene Gas

The full bank has 337 more G-60 questions like these. Get the full G-60 practice for $29.

G-60 exam questions people ask

How many questions are on the G-60 exam?
The FDNY's Notice of Exam says: G-60: 35 questions in 53 minutes. You need at least 70% to pass.
Where do I take the G-60 exam?
At FDNY Headquarters, 9 MetroTech Center, Brooklyn. It is multiple-choice questions on a touch-screen computer, with a time limit. The FDNY's general Notice of Exam lists a $25 application fee.
Are these the real exam questions?
No. Every question here is original, written from the study material the FDNY publishes free. The real exam uses its own questions, so learn the material rather than memorizing answers.
Do I need anything special to take the G-60?
The Notice of Exam lists no letter or course requirement specific to the G-60. There is no alternative issuance procedure (AIP): you must pass the computer exam at FDNY Headquarters. The booklet says G-60 passers are not required to get the G-41, but may pay an additional $25 fee to obtain it.

Not sure this is the right certificate? See which certificate you need, and read what happens on exam day.

G-60 guides

Fire Guard Test is an independent practice resource. We are not affiliated with, endorsed by, sponsored by, or connected to the New York City Fire Department (FDNY), the City of New York, or any accredited school or training provider. "FDNY" is a trademark of the City of New York and is used here only to describe the exams our practice material helps you prepare for. Every question here is original, written from the study material the FDNY publishes free of charge; none is a real exam question, and our mock exams are not identical to the real exam. Exam rules, fees and study material can change without notice, so always check the current official study material and Notice of Exam on nyc.gov before your test. Practicing here does not guarantee that you will pass or be issued a Certificate of Fitness, and nothing on this site is legal or fire-safety compliance advice.