Skip to content
Fire Guard Test

NYC Certificate of Fitness practice

C-14 practice test: chemical lab supervision

C-14 Certificate of Fitness (COF): Supervision of Chemical Laboratories (non-production)

People who supervise non-production chemical laboratories, such as research, testing, school and hospital labs, including storage and use of hazardous materials.

C-14 exam

50 questions

76 minutes

To pass

70% or more

Multiple choice, touch screen

Where

9 MetroTech

FDNY HQ, Brooklyn

From the FDNY's official C-14 Notice of Exam and study material (Revised January 2026 (contact/payment info)), checked September 29, 2026. Download the official booklet (PDF, nyc.gov) and check it before your exam, because the FDNY can change it without notice.

Before you apply

Free C-14 sample: 10 questions

No account needed. You'll see the answer, an explanation and where it is in the official study material after each question.

Question 1 of 10

A research lab keeps a small solvent inventory. Once its stored flammable and combustible liquids go above what amount does it fall under the Fire Code as a non-production laboratory needing C-14 supervision?

The full C-14 question bank

220 original questions across 14 topics from the study material, each with an explanation. Practice by topic, then sit timed mocks at the real length (C-14: 50 questions in 76 minutes).

One-time payment, 12 months of access, 14-day money-back guarantee. Already bought it? Practice · Timed mock

C-14 practice test questions and answers

The 10 free sample questions above, with the answer, the reason and the place in the official study material. Open one to check it.

  1. 1. A research lab keeps a small solvent inventory. Once its stored flammable and combustible liquids go above what amount does it fall under the Fire Code as a non-production laboratory needing C-14 supervision?Show answer
    • A. 1 gallon
    • B. 5 gallons
    • C. 10 gallons
    • D. 30 gallons

    Answer: A. The C-14 requirement applies when flammable or combustible liquid storage in a lab or chemical storage room exceeds 1 gallon. Below that amount (and below the gas threshold) the lab is not regulated as a non-production laboratory.

    Topic: Scope and C-14 coverage · Official study material: Introduction, B. Certificate of Fitness Coverage

  2. 2. A solvent has a closed-cup flash point of 120°F. How is it defined in the Fire Code?Show answer
    • A. Flammable liquid
    • B. Pyrophoric liquid
    • C. Flammable solid
    • D. Combustible liquid

    Answer: D. The dividing line is a 100°F closed-cup flash point. At 100°F or higher the liquid is combustible; below 100°F it is flammable.

    Topic: Definitions · Official study material: Part I, 1. Definitions

  3. 3. A pre-existing lab has 2-hour fire-rated construction and sprinklers. Which laboratory type is it?Show answer
    • A. Type I
    • B. Type II
    • C. Type III
    • D. Type IV

    Answer: A. Pre-existing Type I labs have a 2-hour fire rating with sprinklers. Type II is 1-hour with sprinklers, Type III is 2-hour without, and Type IV is 1-hour without.

    Topic: Hazard classes and NFPA 704 · Official study material: Part I, 2.1 Laboratory Unit Hazard Classification

  4. 4. How long is a Fire Department permit for a non-production laboratory valid?Show answer
    • A. 6 months
    • B. 12 months
    • C. 24 months
    • D. 36 months

    Answer: B. Permits are valid for 12 months only; each permit or renewal requires an inspection.

    Topic: Permits and good work practices · Official study material: Part II, 3.1 Fire Department Permit

  5. 5. What is the maximum amount of flammable liquids allowed in a pre-existing Type I laboratory?Show answer
    • A. 15 gallons
    • B. 20 gallons
    • C. 25 gallons
    • D. 30 gallons

    Answer: D. Table II-2 allows 30 gallons of flammable liquids in a Type I lab, 25 in Type II, 20 in Type III and 15 in Type IV.

    Topic: Quantity limits and storage rooms · Official study material: Part II, 4.1 Flammable & Combustible Liquids Quantity Limitation (Table II-2)

  6. 6. What wording does the newer Fire Department rule require on the outside of each new laboratory?Show answer
    • A. Danger - Authorized Chemists Only - No Admittance
    • B. Warning - Fire Hazard Area
    • C. Laboratory - Keep Door Closed
    • D. Laboratory - Caution: Hazardous Materials

    Answer: D. New labs need a sign reading "Laboratory - Caution: Hazardous Materials." The older wording, "Laboratory - Potentially Hazardous Substances," is still acceptable.

    Topic: Signs and placards · Official study material: Part II, 4.B (1) Hazard identification signs

  7. 7. A vendor offers a ductless fume hood that filters the air and returns it to the room. May it be used in a New York City lab?Show answer
    • A. Yes, as long as the filter cartridge is changed every month
    • B. Yes, but only for work with acids and bases
    • C. Yes, as long as the lab is fully sprinklered
    • D. No, hoods that return filtered air to the room are not allowed

    Answer: D. Filtered, recirculating hoods are used in other places but are not permitted in New York City. Air pulled out by chemical fume hoods must not be recirculated.

    Topic: Fume hoods and ventilation · Official study material: Part II, 4.B (2) Fume hoods and exhaust systems

  8. 8. A new lab manager wants to arrange the chemical stockroom. How should chemicals be organized first?Show answer
    • A. Alphabetically by chemical name, for easy finding
    • B. By compatibility, keeping hazard categories apart
    • C. By container size, largest on the bottom shelf
    • D. By date of purchase, oldest at the front

    Answer: B. Chemicals should be organized first by compatibility, not alphabetical order, with incompatible materials segregated by hazard category.

    Topic: Chemical storage and handling · Official study material: Part II, 5.1 Chemical Storage and Handling

  9. 9. The C-14 holder learns that the lab's sprinkler system needs repair. Whom should he or she notify?Show answer
    • A. The chemical supplier
    • B. The lab's students
    • C. The building's impairment coordinator
    • D. No one; C-14 holders supervise sprinkler maintenance themselves

    Answer: C. C-14 holders do not supervise fire protection maintenance, but if they learn a system needs service they should notify the building impairment coordinator.

    Topic: Fire protection and extinguishers · Official study material: Part II, 6. Fire Prevention and Protection Systems

  10. 10. Who must cause laboratory emergency plans to be prepared?Show answer
    • A. The FDNY
    • B. The chemical supplier to the laboratory
    • C. The owner of the laboratory
    • D. The local police precinct

    Answer: C. The owner is responsible for having emergency plans prepared for both new and pre-existing labs.

    Topic: Emergency plans and procedures · Official study material: Part II, 8. Emergency Plans

The full bank has 210 more C-14 questions like these. Get the full C-14 practice for $29.

C-14 exam questions people ask

How many questions are on the C-14 exam?
The FDNY's Notice of Exam says: C-14: 50 questions in 76 minutes. You need at least 70% to pass.
Where do I take the C-14 exam?
At FDNY Headquarters, 9 MetroTech Center, Brooklyn. It is multiple-choice questions on a touch-screen computer, with a time limit. The FDNY's general Notice of Exam lists a $25 application fee.
Are these the real exam questions?
No. Every question here is original, written from the study material the FDNY publishes free. The real exam uses its own questions, so learn the material rather than memorizing answers.
Do I need anything special to take the C-14?
The Notice of Exam requires a recommendation letter from your employer on official letterhead, confirming your training on the lab's emergency plan and hazardous materials. It also requires one of these qualifications, with proof such as a transcript: a bachelor's degree in chemistry, biology, a related science or certain engineering fields; an associate degree in those fields plus an employer lab safety course; 60 college credits (at least 21 in science or engineering) plus an employer lab safety course; New York State permanent certification as a chemistry or biology teacher (grades 7 to 12); or a New York State clinical laboratory technology license. Check the booklet for the exact wording. The Notice of Exam says reference material is provided in the exam room if your exam needs it.

Not sure this is the right certificate? See which certificate you need, and read what happens on exam day.

C-14 guides

Fire Guard Test is an independent practice resource. We are not affiliated with, endorsed by, sponsored by, or connected to the New York City Fire Department (FDNY), the City of New York, or any accredited school or training provider. "FDNY" is a trademark of the City of New York and is used here only to describe the exams our practice material helps you prepare for. Every question here is original, written from the study material the FDNY publishes free of charge; none is a real exam question, and our mock exams are not identical to the real exam. Exam rules, fees and study material can change without notice, so always check the current official study material and Notice of Exam on nyc.gov before your test. Practicing here does not guarantee that you will pass or be issued a Certificate of Fitness, and nothing on this site is legal or fire-safety compliance advice.