The certificates
FDNY G-60 Exam Guide: Torch Use of Flammable Gases
What the G-60 exam covers, part by part: permits, hot work rules, fire watch, oxy-fuel and LPG torches, gas cylinders and extinguishers.
Published · 6 min read · Facts last verified October 12, 2026
Studying for the exam? Try our G-60 practice test or F-60 practice test, with free sample questions written from the FDNY's study material.
The G-60 is the New York City Certificate of Fitness for people who run the torch: oxy-fuel cutting and welding, brazing and soldering, and LPG or CNG torch work, including torch-applied roofing. The exam is 35 multiple-choice questions in 53 minutes, and you need at least 70% to pass. It covers the whole FDNY study booklet, which has five parts. This guide walks through each part, says what the booklet expects you to know, and flags the numbers that are easy to mix up.
Why the G-60 matters
The booklet opens with what it calls an important code change: any hot work operation, including torch work with a flammable gas (with or without oxygen) and torch-applied roofing, must be personally done by a Certificate of Fitness holder. Its table then sorts torch work by certificate. Oxygen with a flammable gas, LPG or CNG for any hot work is the G-60. LPG or CNG roofing torches can be run by a G-41, G-42 or G-60 holder. Oxygen with piped natural gas in jewelry and dental labs is the G-61. If you are unsure which card your job needs, ask your employer, and see which certificate you need.
The exam at a glance
| Fact | What the G-60 Notice of Exam says |
|---|---|
| Questions | 35 multiple choice, on a touch-screen computer |
| Time limit | 53 minutes |
| Passing score | At least 70% (25 of 35 correct) |
| Scope | The entire booklet |
| Special requirements | None listed beyond the general rules; G-60 passers may pay an extra $25 for the G-41 without a separate exam |
| Alternative issuance (AIP) | None: you must pass the computer exam at FDNY Headquarters |
Blank answers and answers with more than one choice marked are scored wrong, and there is no penalty for guessing, so answer every question. The booklet also says you should be familiar with NFPA 51B and Fire Code Chapters 35 and 38, not just the booklet. For applying, fees and exam day, see how to get a G-60 certificate.
Introduction: certificates, permits and authorization
Expect questions on the paperwork before any torch is lit. The booklet distinguishes three things:
- Your Certificate of Fitness. Keep it on you or readily available for FDNY inspection while you work. The booklet also sets when connecting LPG or CNG containers needs a certificate (LPG containers of 16.4 oz or more, CNG containers over 8.7 SCF).
- FDNY permits. Required, among other cases, for storing or using a flammable gas with oxygen, any flammable gas over 400 SCF (about 47 lbs of LPG), oxygen over 504 SCF, any open flame on a torch-applied roof, and flammable gas without oxygen at a construction site that needs a Department of Buildings permit. Permits are either site-specific or citywide, run for at most 12 months and cannot be transferred.
- The hot work program authorization. This is not an FDNY document. The responsible person designated by the owner signs it, the sample form is good for one day only, and it stays available for inspection during the work and for 48 hours after.
The booklet's LPG permit table is a favorite source of number questions. Learn it with the construction-site figures, which are lower: for example 46 containers of 16.4 oz in general, but 20 on a construction site.
Part 1: torch operation, locations and fire watch
Part 1 is the biggest part and overlaps heavily with the F-60 fire guard booklet. Key points:
- Restricted areas. No hot work where sprinklers are impaired (construction sites excepted, with precautions), where a standpipe is impaired (except below 75 feet on construction sites), where an explosive atmosphere could exist, near readily ignitable materials, or on vessels at a dock under construction or repair.
- LPG and CNG prohibitions. Two tables list where LPG and CNG can't be stored or used (below grade, residential occupancies, building roofs, vehicles, space heating) and the narrow exceptions, such as emergency indoor repairs and manhole operations. Filling or transferring between containers is prohibited.
- The pre-hot work check. Done before authorization and at least daily. It covers equipment condition, clearance from combustibles (35 feet for cutting or welding, 25 feet for other hot work, or shielding), protected openings, sprinklers left in service, extinguishers, and certificates and permits for everyone doing the work.
- Torch and arc rules. One torch per person, never left lit and unattended. Arc welding cables grounded, power off when the welder walks away.
- Fire watch. Required for all hot work, with no other duties, for at least 30 minutes after the work stops. An F-60 fire guard is required at construction sites, on rooftops and roofing jobs, and when a citywide permit holder does the torch work. LPG, CNG and arc welding work gets inspections at 30 minutes and again at 1 hour.
Our F-60 fire watch guide goes deeper on the watch itself.
Part 2: gas torch equipment
This is G-60 territory that the F-60 booklet barely touches. You need to know:
- Blowtorch versus oxy-fuel. A blowtorch (such as a propane roofing torch) mixes in air from around it. An oxy-fuel torch has separate oxygen and fuel cylinders, mixes the gases inside the torch, and burns much hotter. Oxygen itself does not burn; it makes other things burn more fiercely, which is why it must never be used to dust off clothing.
- Pressures and temperatures. Oxygen is stored up to 2,200 psi. Fuel gas, and acetylene above all, must not be used above 15 psi. Oxyacetylene reaches about 6,000°F; brazing and soldering run around 840°F.
- Procedures. How to set up, light (friction lighter, never a match) and shut down oxy-fuel torches and blowtorches; acetylene valves opened no more than about 1½ turns; torch valves closed and gas shut off for breaks of an hour or more; oxygen and acetylene containers removed from construction work areas at day's end, except for breaks up to 2 hours.
- Backfire and flashback. A backfire is the flame going out with a pop. A flashback is flame burning inside the torch or hose, with a hiss or whistle, and is the more serious sign. Know the order of shutoff for each.
- Protection. Ventilation, MEA-approved equipment, and flame-resistant PPE with no cuffs or pockets to catch sparks.
Part 3: compressed gas containers
Part 3 is where many G-60 questions come from, because it is full of specific rules:
- General handling. Identify gas by label, not color. Refilling is illegal in NYC. Empties are treated like full containers. LPG and CNG containers stay upright and secured, never stacked or on shelves, and away from heat above 125°F.
- Hoses and regulators. DOT-approved hose rated for 350 psi, no rubber slip connections, no longer than 30 feet, and never through walls, floors or ceilings indoors.
- Moving containers. Never rolled on the rim or lifted by the cap or valve; carts with individual restraints; elevators between floors, with special rules for LPG containers over and under 20 lbs.
- Separation distances. 20 feet between stored fuel gas or oxygen and combustibles, 20 feet between oxy-fuel carts, and for oxygen and acetylene storage on a torch floor: 25 feet from ignition sources and 50 feet from compressors, air intakes and other flammable gas storage.
- The gases. Acetylene (garlic odor, never above 15 psi, no copper splices), LPG (heavier than air, expands about 269 times as it vaporizes, containers tested every five years) and CNG (mostly methane, lighter than air, must be odorized).
- Leak checks. Soap and water only, never a flame. Ice on a connector means return the container to the supplier; ice on the container itself means call 911.
Parts 4 and 5: extinguishers and lithium-ion batteries
Part 4 covers extinguisher ratings for hot work (at least 2-A:20-B:C within 30 feet, or 3-A:40-B:C for torch-applied roofing), P.A.S.S., fire classes, the rule to shut off the gas before putting out a gas fire, mounting heights, tags and inspections. Our fire extinguisher guide covers these across all the booklets. Part 5 is the FDNY's lithium-ion battery safety material, shared with the other booklets; see the lithium-ion guide.
How to study for it
Read the current booklet from nyc.gov end to end, then focus on the numbers: 16.4 oz and 8.7 SCF, 400 and 504 SCF, 15 psi, 35 and 25 feet, 30 feet, 20/25/50 feet, 30 minutes and 1 hour. Then test yourself. Our G-60 practice questions article has worked examples, the G-60 practice page has free questions, and the full bank with timed 35-question mocks is on the pricing page. Practice can show you where your gaps are, but it can't guarantee a pass, and our questions are original, not the real exam's.
Practice for the exam
Original questions written from the FDNY's free study material, with an explanation for every answer. Not real exam questions, and no promise about any result.
Sources
- Study Material for the Certificate of Fitness Examination for Use of Flammable Gases with Oxygen or Use of LPG/CNG for Hot Work Operations (Citywide) G-60 — New York City Fire Department (FDNY). Accessed October 12, 2026. Revised January 2026 (Contact/Payment info)
- Certificates of Fitness — New York City Fire Department (FDNY). Accessed October 12, 2026.
Fire Guard Test is an independent practice resource. We are not affiliated with, endorsed by, sponsored by, or connected to the New York City Fire Department (FDNY), the City of New York, or any accredited school or training provider. "FDNY" is a trademark of the City of New York and is used here only to describe the exams our practice material helps you prepare for. Every question here is original, written from the study material the FDNY publishes free of charge; none is a real exam question, and our mock exams are not identical to the real exam. Exam rules, fees and study material can change without notice, so always check the current official study material and Notice of Exam on nyc.gov before your test. Practicing here does not guarantee that you will pass or be issued a Certificate of Fitness, and nothing on this site is legal or fire-safety compliance advice.
Exam rules, fees and study booklets change. Check the current FDNY study material and Notice of Exam for your certificate before you rely on anything here.